英语翻译By correlating the 1D projections obtained at two differenttimes,it is possible to obtain precise information about therelative displacement that occurred.Previous results madewith a sphere at a static position give an average error of0.0

来源:学生作业帮助网 编辑:作业帮 时间:2024/05/15 02:06:32
英语翻译By correlating the 1D projections obtained at two differenttimes,it is possible to obtain precise information about therelative displacement that occurred.Previous results madewith a sphere at a static position give an average error of0.0

英语翻译By correlating the 1D projections obtained at two differenttimes,it is possible to obtain precise information about therelative displacement that occurred.Previous results madewith a sphere at a static position give an average error of0.0
英语翻译
By correlating the 1D projections obtained at two different
times,it is possible to obtain precise information about the
relative displacement that occurred.Previous results made
with a sphere at a static position give an average error of
0.064 mm between the real displacement and the one
measured experimentally.In the dynamic case (i.e.when
several acquisitions are repeated rapidly),this value is found
to be approximately 1.2 mm [2].
To be able to get an absolute position out of this method,
we need to know the exact position of the device during the
acquisition of the correlation mask.This could theoretically
be done by placement of the ferromagnetic bead in a precise
phantom that would be centered as precisely as possible
inside the MRI bore.The correlation mask would be
acquired,then the phantom removed prior to place the
patient inside the bore.This method has several drawbacks.
The most important drawback is that the center of the MRI
gradients (where the magnetic field is always Bo when
gradients are applied) is known to migrate with time and itsposition is difficult to determine precisely.This would add
an uncertainty to the position of the bead.
A more suitable approach has been developed,allowing a
fast and precise determination of the position of the
ferromagnetic entity at any time without requiring any
special setup or manipulation while not being affected by
the ferromagnetic susceptibility distortion.This autocalibration
method simply involves the convolution of two
projections acquired with opposite readout gradients.

英语翻译By correlating the 1D projections obtained at two differenttimes,it is possible to obtain precise information about therelative displacement that occurred.Previous results madewith a sphere at a static position give an average error of0.0
由相关的维推算取得两个不同时代 就有可能获得确切消息相对位移发生.以往成绩取得了一球静止的位置,平均误差为0.064毫米的位移和现实之间的一个实验测量.在动态情况下(即当数收购是迅速重复) 这个价值被发现有大约1.2毫米[2].能够得到一个绝对位置出这个方法 我们需要知道确切位置在仪器购置相关面罩.这可以从理论上应由放置在一个确切的铁磁珠串幽灵将集中尽可能准确的MRI膛内.后天将相关掩模,然后拆除前广场歌声病人膛内.这种方法有几个缺点.最重要的缺点是正中的梯度磁共振(凡波当梯度磁场总是适用)已知迁移时间和itsposition恰恰是难以确定.这将增添不明朗的珠子位置.较适合已发展、 允许快速、精确测定铁磁实体的地位随时无需任何特殊设置或操纵,而不是受铁磁畸变敏感性.这仅仅涉及autocalibration褶两种方法推算后天相向读取梯度.

藉由使有相互关系在二点被获得的 1D 发射不同的
时代, 获得关于的精确资讯是可能的那
发生的比较的换置。 早先的结果制造
藉由一个球体在一个静态的位置给平均学名差错
0.064 毫米在真正的换置之间和那一
实验式地测量了。 在动态的情形 (也就是当
一些获得快速地被重复), 这价值被发现
大约是 1.2 毫米 [2].
能够把一个...

全部展开

藉由使有相互关系在二点被获得的 1D 发射不同的
时代, 获得关于的精确资讯是可能的那
发生的比较的换置。 早先的结果制造
藉由一个球体在一个静态的位置给平均学名差错
0.064 毫米在真正的换置之间和那一
实验式地测量了。 在动态的情形 (也就是当
一些获得快速地被重复), 这价值被发现
大约是 1.2 毫米 [2].
能够把一个绝对的位置赶出这一个方法,
我们需要知道装置的精确位置在那期间
相互关系的获得戴面具。 这可以理论上
被强磁性珠子的安置做在一精确的
会尽可能精确地被集中的幻影
在磁共振成像令人讨厌的人内。 相互关系面具会是
已取得的, 然后幻影在地方之前移走了那
在令人讨厌的人内病人。 这一个方法有一些不利点。
最重要的不利点是那磁共振成像的中心
梯度 (哪里磁场总是 Bo 当
梯度被应用) 被知道以时间和 itsposition 移动难以精确地决定。 这会增加
到珠子的位置的不确定。
比较适当的方式已经被发展, 允许一
位置的快速的和精确决心那
强磁性实体随时没有需要任何的
特别的装备或处理当不的时候被影响被
强磁性感受性扭曲。 这 autocalibration
方法只是包括二的回旋
发射以相反的数据解析梯度获得了。

收起